Used Geppert Engineering Vacuum Mixer

Inventory Number: 64923
Now (USD): $2,950.00

Geppert Engineering Vacuum Mixer. Approximate dimensions 13" diameter by 18" deep stainless steel chamber with a 1.5 HP 3450 rpm ac motor. 230V, 3Ph, 60Hz, 4A

Product Details

Used Granville Phillips 835100-YG-1D

Inventory Number: 64669
Now (USD): $1,950.00

MKS Granville Phillips 835100-YG-1D Vacuum Quality Monitor Gauge. Gauge used for RGA System. The Granville-Phillips® 835100-YG-1D Gauge for the VQM Vacuum Quality Monitor System measures 1 to 145 amu, with a demountable envelope. NEW, NEVER USED. 2 AVAILABLE

Product Details

Used Granville Phillips 332 VAcuum Gauge Controller

Inventory Number: 64766
Now (USD): $150.00

Granville Phillips 332 Vacuum Gauge Controller. P/N 20332-449

Product Details

Used Haskris WW3

Inventory Number: 64747
Now (USD): $2,500.00

Haskris WW3 3 Channel Heat Exchanger. Heat exchanger with 3 separate PD-2 water pumps each capable of 3.5 GPM flow at 50 PSI. Cooling capacity up to 50,000 watts depending on house cooling water temperature and flow.208/230V, 1Ph, 60Hz, 9.4A

Product Details

Used Huber Ministat 240

Inventory Number: 64803
Now (USD): $8,500.00

NEW! Huber Ministat 240 & Pilot One -45°C To +200°C Compact Cooling Bath Circulation Thermostat.

Huber Ministats are the smallest cooling circulator in the world. Their small dimensions allow Ministats to be placed in the smallest of spaces, for example in a laboratory fume cupboard or inside technical plant. Despite their minimal size the systems are extensively fitted out and offer sufficient performance for temperature control of photometers, refractometers, viscometers, distillation apparatus, reaction vessels and mini-plants. The main applications are using external applications however the bath opening allows objects to be thermoregulated directly in a thermostat bath. A powerful pressure/suction pump with an infinitely controlled rotational speed ensures optimal circulation. The maximum pressure can also be regulated by an optional pressure sensor, meaning that sensitive glass reactors and apparatus can reliably be protected from breakage. Additionally, Ministats offer the Pilot ONE controller as standard with a colour TFT display and comfortable operator guidance. Analogue connections according to NAMUR are available via the optional Com.G@te module allowing Ministats to integrate into plant and process control systems.


General information & temperature controller
Temperature range  -45...200 °C
Temperature stability ±0.02 °C
Controller Pilot ONE  (E-grade "Basic")
Safety class  III / FL  
Protection class  IP20  
Dimensions (W x D x H) 300 x 465 x 516 mm  |  11.81 x 18.31 x 20.31 inches
Weight 44 kg  |  97.02 pounds
Heating / cooling capacity
Heating capacity  1,6 kW
Cooling capacity
100 20 0 -10 -20 -40  °C
0,6 0,6 0,55 0,42 0,35 0,05  kW
Cooling machine air-cooled  
Refrigerant (ASHRAE, GHS) R290 (A3, H220) (0,099 kg)
Circulation pump
Pressure pump max.  22 lpm ; 0.7 bar  |  5.81 gpm ; 10.15 psi
Suction pump max.  16 lpm ; 0.4 bar  |  4.23 gpm ; 5.8 psi
Pump connection  M16x1 AG male  
Permissible viscosity  50 mm²/s
Pump speed adjustable Yes
Connections
Pt100 connection  Pt100  
Digital interface  RS232, Ethernet, USB Device, USB Host


Product Details

Used Innovative Technology S One M

Inventory Number: 64552
Now (USD): $9,000.00

Innovative Technology S-One-M Glove Box with Freezer. Stainless steel construction glove box. Large and small antechambers. Refrigerator/Freezer mounted to one side of glove box. Gas purification system with blower and new desiccant media installed at time of refurbishment. Does not come with a vacuum pump at this price.

Product Details

Used Ircon 10-99C20

Inventory Number: 64687
Now (USD): $295.00

Ircon 10-99C20 Infrared Thermometer.

Product Details

Used JDS Uniphase SWS20002-A-N1

Inventory Number: 64673
Now (USD): $1,250.00

JDS Uniphase SWS2002-A-N1 Source Optics Module.

Features:
  • Reduces Production Test Cost
  • ± 0.002 nm Absolute Wavelength Accuracy
  • High Speed Scanning
  • Distributed Architecture
  • Up to 128 Detector Channels for Device Characterization

The JDS Uniphase SWS2000 Series Swept Wavelength System is a fast, accurate and flexible test solution for characterizing the wavelength dependence of passive optical components. The SWS system consists of: a tunable laser source, a source optics module, a receiver chassis, a control module, and one or more detector modules and application software.

Product Details

Used Jelight 144AX

Inventory Number: 64893
Now (USD): $4,950.00

Jelight 144AX UV Ozone Cleaner. UVO cleaning method is a photo-sensitized oxidation process in which the contaminant molecules of photoresists, resins, human skin oils, cleaning solvent residues, silicone oils and flux are excited and/or dissociated by the absorption of short wavelength UV radiation. Tray Size: 12” x 12” x 3”. 120V, 60 Hz, 5A. CE

Product Details

Used Jeol IB-09010CP

Inventory Number: 64860
Now (USD): $45,000.00

Jeol IB-09010CP Cross Section Polisher Argon Beam Milling System.
Produces pristine cross sections of samples – hard, soft, or composites without smearing, crumbling, distorting, or contaminating them in any way. The ability to create perfect cross sections of paper, shale, yeast, latex beads, coatings, and wire bonds, or to create a mirrored surface on soft materials such as gold, polymers, ceramics, and glass has greatly enhanced research and analysis for many of our customers. The CP uses an argon beam to mill cross sections or polish virtually any material that is affi xed to the continuously rotating sample holder. The high power optical microscope allows the user to position a sample to within a few microns of the precise cross section position. During milling, the sample is rocked automatically to avoid creating beam striations on the cross sectioned surface. Due to the glancing incidence of the ion beam, argon is not implanted into the sample surface. 100-120V, 50/60Hz, 5A

Product Details